Cement Percent Effect on the Shear and Interface Strength of Remolded Cement Treated Sand

Keywords: cement treated sand, interface strength, Remolded soil, Shear strength

Abstract

This research aims to simulate the behavior of remolded cement treated poorly graded sand in term of shear and interface strength using the direct shear test. Different percentages of cement up to 15% by weight are added to the soil samples. Compacted cement treated soil samples are prepared at the optimum moisture content and left for 28 days in the humidity room then distributed to use them for the remolding samples preparation. The shear strength parameters for both cases soil to soil interface and concrete to soil interface are predicted, where the results show that the interface strength parameters are higher than the shear strength parameters of the remolded soil samples. The increase in cement percent increases the cohesion (C) of the treated soil, whereas the interface cohesion (Cint.) has a maximum value at 10% of added cement, and the maximum percent between cohesion (Cint.) and soil cohesion (C) is of 76.2% at 0% added cement. Moreover, the results show an increase in the interface angle of friction (δ) and a decrease in the angle of friction (φ) as the percent of cement increases. The maximum percent between interface angle (δ) and angle of friction (φ) is 63.5% at 15% of the added cement. The hardened cement in the remolded case adheres to sand grains and works as soil grains with different sizes that lead to changes in the shear properties of the soil.

Downloads

Download data is not yet available.

Author Biography

Zahraa N. Rashied, Department of Geotechnical Engineering, Faculty of Engineering, Koya University, Koya KOY45, Kurdistan Region - F.R. Iraq

Zahraa N. Rashied is an Assistant Prof. at the Department of Geotechnical Engineering, Faculty of Engineering, Koya University. He got the B.Sc. degree in Civil Engineering, the M.Sc. degree in Structural Engineering and the Ph.D. degree in Geotechnical Engineering. His research interests are in soil improvement, slop stability analysis, soil dynamics and soil classification. Dr. Zahraa is a member of the Kurdistan Union of Engineers and the Iraqi Union of Engineers.

References

Acar, Y.B., Durgunoglu, H.T. and Tumay, M.T., 1982. Interface properties of sand. Journal of Geotechnics, 108, pp.648-654.

ASTM, 2020. Annual Book of American Standards for Testing and Materials, Part 8. Vol. 4. ASTM, United States.

Braja, M.D. and Sobhan, K., 2014.In: Shortt CM, editor. Principles of Geotechnical Engineering. 8th ed. Christopher M. Shortt.

Broms, B.B., 1963. Discussion on bearing capacity of piles in cohesionless soils. Journal of the Soil Mechanics Division of the ASCE, 89, pp.125-126.

Feng, D.K., 2012. Three-Dimensional Constitutive Laws, Mechanism and Model of Gravel-Structure Interfaces, PhD Thesis, Tsinghua University, Beijing.

Hou, W.J., 2008. Research on monotonic and cyclic behavior and constitutive model of three-dimensional soil–structure interface, PhD thesis, Tsinghua University, Beijing.

Hu, L.M. and Pu, J.L., 2001. Experimental study on mechanical characteristics of soil-structure interface. Chinese Journal of Geotechnical Engineering, 23, pp.431-435.

Hu, L.M. and Pu, J.L., 2003. Application of damage model for soil-structure interface. Computers and Geotechnics, 30, pp.165-183.

Noorany, I., 1985. Side Friction of Piles in Calcareous Sands, Proceedings of the 11th International Conference of Soil Mechanics and Foundation Engineering, Cambridge, USA, pp.12-16.

Potyondy, J.G., 1961. Skin friction between various soils and construction materials. Geotechnique, 11, pp.831-853.

Suganya, K. and Sivapullaiah, P.V., 2020. Compressibility of remolded and cement-treated Kuttanad soil. Soils and Foundations, 60, pp.697-704.

Uesugi, M., Kishida, H. and Uchikawa, Y., 1990. Friction between dry sand and concrete under monotonic and repeated loading. Soils and Founds, 30, pp.115-128.

Watabe, Y., Kaneko, T. and Wantanabe, Y., 2016. Cement mix proportion for treated soils recycled from a cement treated soil. Japanese Geotechnical Society Special Publication, 4, pp.168-172.

Published
2022-02-19
How to Cite
Rashied, Z. N. (2022) “Cement Percent Effect on the Shear and Interface Strength of Remolded Cement Treated Sand”, ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY, 10(1), pp. 6-9. doi: 10.14500/aro.10805.